Products

Find the emergency lighting systems for your project.
Series

DIANA IP66

Superior robustness for demanding environments: Enduring safety.

Xena IP66 is an emergency luminaire designed to withstand the most adverse conditions, thanks to its exceptional IP66 and IK10 protection. Perfect for industrial environments, warehouses, or outdoor areas where durability and resistance to humidity and impact are crucial, it guarantees uninterrupted safety and operation.

Key Specifications:
• Luminous flux: from 55 to 800 lumens in emergency mode, and from 55 to 405 lumens in permanent modus.
• Duration: 1 or 3 hours, with LiFePO₄ or Ni-Cd batteries.
• Polycarbonate body.
• Control: AutoTest, DALI2 or Wireless SmartZ®.

Warranty
10
Years
Warranty
5
Years
Warranty
2
Years
Share
Imagen de producto
Imagen de producto
Imagen de producto
Imagen de producto
Imagen de producto
Vídeo de producto

Product

Body
Recycled Polycarbonate, Polycarbonate
Ingress Protection
IP66
Impact protection
IK10
Emergency
55 ~ 800 lm
Mains
55 ~ 405 lm
Duration
1 h, 3 h
Battery
LiFePO₄, Ni-Cd
Charging time
12 h, 24 h
Supply
230V 50Hz, 230Vac/dc, 24Vac/dc
Colour temperature
4000 K
Working temperature
0~40 °C, -20~40 °C

EN-303-446-1

EN-60598-1

EN-60598-2-22

EN-62034

EN-62386

CE
CE
UK
UK
CMIM
CMIM
Aenor N Sustainable Product Certificate
Aenor N Sustainable Product Certificate
Aenor product certificate
Aenor product certificate
ENEC product certificate
ENEC product certificate
IECEE International Product Certificate
IECEE International Product Certificate
Civil Defense product certificate
Civil Defense product certificate
WallSurface
RecessedX
CeilingSurface
RecessedX
Transparent
Battery systemControl systemEmergencyMainsType*DurationBatteryColourWarrantyCertificationsPart number
Self-containedStandard75 lmNM1 h3.6V-0.3Ah Ni-CdTransparent2 YearsCE UK CMIMLXE3100CN
Self-containedStandard95 lmNM1 h3.6V-0.3Ah Ni-CdTransparent2 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEELXE3100C
Self-containedStandard180 lmNM1 h3.6V-0.8Ah Ni-CdTransparent2 YearsCE UK CMIMLXE3200CN
Self-containedStandard225 lmNM1 h3.6V-0.8Ah Ni-CdTransparent2 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEELXE3200C
Self-containedStandard380 lmNM1 h3.6V-1.6Ah Ni-CdTransparent2 YearsCE UK CMIMLXE3500CN
Self-containedStandard450 lmNM1 h3.6V-1.6Ah Ni-CdTransparent2 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEELXE3500C
Self-containedStandard505 lmNM1 h6.0V-1.6Ah Ni-CdTransparent2 YearsCE UK CMIMLXE3600CN
Self-containedStandard600 lmNM1 h6.0V-1.6Ah Ni-CdTransparent2 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEELXE3600C
Self-containedStandard675 lmNM1 h6.0V-1.6Ah Ni-CdTransparent2 YearsCE UK CMIMLXE3800CN
Self-containedStandard800 lmNM1 h6.0V-1.6Ah Ni-CdTransparent2 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEELXE3800C
Self-containedStandard120 lmNM3 h3.6V-1.6Ah Ni-CdTransparent2 YearsCE UK CMIMLXE3150C3N
Self-containedStandard150 lmNM3 h3.6V-1.6Ah Ni-CdTransparent2 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEE Civil DefenseLXE3150C3
Self-containedAutoTest75 lmNM1 h3.6V-0.3Ah Ni-CdTransparent2 YearsCE UK CMIMLXE9100XN
Self-containedAutoTest95 lmNM1 h3.6V-0.3Ah Ni-CdTransparent2 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEELXE9100X
Self-containedAutoTest180 lmNM1 h3.6V-0.8Ah Ni-CdTransparent2 YearsCE UK CMIMLXE9200XN
Self-containedAutoTest225 lmNM1 h3.6V-0.8Ah Ni-CdTransparent2 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEELXE9200X
Self-containedAutoTest380 lmNM1 h3.6V-1.6Ah Ni-CdTransparent2 YearsCE UK CMIMLXE9500XN
Self-containedAutoTest390 lmNM1 h3.2V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEELXE9400LX
Self-containedAutoTest390 lmNM1 h3.2V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIMLXE9400LXN
Self-containedAutoTest450 lmNM1 h3.6V-1.6Ah Ni-CdTransparent2 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEELXE9500X
Self-containedAutoTest505 lmNM1 h4.8V-1.6Ah Ni-CdTransparent2 YearsCE UK CMIMLXE9600XN
Self-containedAutoTest600 lmNM1 h4.8V-1.6Ah Ni-CdTransparent2 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEELXE9600X
Self-containedAutoTest675 lmNM1 h6.0V-1.6Ah Ni-CdTransparent2 YearsCE UK CMIMLXE9800XN
Self-containedAutoTest800 lmNM1 h6.4V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEELXE9800LX
Self-containedAutoTest800 lmNM1 h6.4V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIMLXE9800LXN
Self-containedAutoTest800 lmNM1 h6.0V-1.6Ah Ni-CdTransparent2 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEELXE9800X
Self-containedAutoTest120 lmNM3 h3.2V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIMLXE9150LX3N
Self-containedAutoTest120 lmNM3 h3.6V-1.6Ah Ni-CdTransparent2 YearsCE UK CMIMLXE9150X3N
Self-containedAutoTest150 lmNM3 h3.2V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEE Civil DefenseLXE9150LX3
Self-containedAutoTest150 lmNM3 h3.6V-1.6Ah Ni-CdTransparent2 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEE Civil DefenseLXE9150X3
Self-containedAutoTest390 lm235 lmM/NM1 h3.2V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEELXE9400LXP
Self-containedAutoTest390 lm235 lmM/NM1 h3.2V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIMLXE9400LXPN
Self-containedAutoTest675 lm405 lmM/NM1 h6.4V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIMLXE9800LXPN
Self-containedAutoTest800 lm400 lmM/NM1 h6.4V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEELXE9800LXP
Self-containedAutoTest120 lm70 lmM/NM3 h3.2V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIMLXE9150LXP3N
Self-containedAutoTest150 lm90 lmM/NM3 h3.2V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEE Civil DefenseLXE9150LXP3
Self-containedDALI2330 lm200 lmM/NM1 h3.2V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIMLXE9400LAPN
Self-containedDALI2390 lm235 lmM/NM1 h3.2V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEELXE9400LAP
Self-containedDALI2675 lm405 lmM/NM1 h6.4V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIMLXE9800LAPN
Self-containedDALI2800 lm400 lmM/NM1 h6.4V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEELXE9800LAP
Self-containedDALI2120 lm70 lmM/NM3 h3.2V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIMLXE9150LAP3N
Self-containedDALI2150 lm90 lmM/NM3 h3.2V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEE Civil DefenseLXE9150LAP3
Self-containedDALI2250 lm150 lmM/NM3 h6.4V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIMLXE9300LAP3N
Self-containedDALI2300 lm180 lmM/NM3 h6.4V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEE Civil DefenseLXE9300LAP3
Self-containedWireless SmartZ®330 lm200 lmM/NM1 h3.2V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIMLXE9400LWPN
Self-containedWireless SmartZ®390 lm235 lmM/NM1 h3.2V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEELXE9400LWP
Self-containedWireless SmartZ®675 lm405 lmM/NM1 h6.4V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIMLXE9800LWPN
Self-containedWireless SmartZ®800 lm400 lmM/NM1 h6.4V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEELXE9800LWP
Self-containedWireless SmartZ®120 lm70 lmM/NM3 h3.2V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIMLXE9150LWP3N
Self-containedWireless SmartZ®150 lm90 lmM/NM3 h3.2V-1.5Ah LiFePO₄Transparent5 YearsCE UK CMIM Aenor N Sustainable Aenor N ENEC IECEE Civil DefenseLXE9150LWP3
Self-containedDALI2605 lmNM1 h6.4V-1.5Ah LiFePO₄Transparent10 YearsCE UK CMIMLXEX9700LAN
Self-containedDALI2720 lmNM1 h6.4V-1.5Ah LiFePO₄Transparent10 YearsCE UK CMIM Aenor N SustainableLXEX9700LA
Self-containedDALI2210 lmNM3 h3.2V-3.0Ah LiFePO₄Transparent10 YearsCE UK CMIMLXEX9230LA3N
Self-containedDALI2250 lmNM3 h3.2V-3.0Ah LiFePO₄Transparent10 YearsCE UK CMIM Aenor N Sustainable Civil DefenseLXEX9230LA3
Self-containedDALI2335 lmM/NM1 h3.2V-1.8Ah LiFePO₄Transparent10 YearsCE UK CMIMLXEX9400LAN
Self-containedDALI2400 lmM/NM1 h3.2V-1.8Ah LiFePO₄Transparent10 YearsCE UK CMIM Aenor N SustainableLXEX9400LA
Self-containedWireless SmartZ®335 lmNM1 h3.2V-1.8Ah LiFePO₄Transparent10 YearsCE UK CMIMLXEX9400LWN
Self-containedWireless SmartZ®400 lmNM1 h3.2V-1.8Ah LiFePO₄Transparent10 YearsCE UK CMIM Aenor N SustainableLXEX9400LW
Self-containedWireless SmartZ®605 lmNM1 h6.4V-1.5Ah LiFePO₄Transparent10 YearsCE UK CMIMLXEX9700LWN
Self-containedWireless SmartZ®720 lmNM1 h6.4V-1.5Ah LiFePO₄Transparent10 YearsCE UK CMIM Aenor N SustainableLXEX9700LW
Self-containedWireless SmartZ®210 lmNM3 h3.2V-3.0Ah LiFePO₄Transparent10 YearsCE UK CMIMLXEX9230LW3N
Self-containedWireless SmartZ®250 lmNM3 h3.2V-3.0Ah LiFePO₄Transparent10 YearsCE UK CMIM Aenor N Sustainable Civil DefenseLXEX9230LW3
Central Battery System (CBS)55 lm55 lm-N/ATransparent2 YearsCE UK CMIMLXE307023N
Central Battery System (CBS)55 lm55 lm-N/ATransparent2 YearsCE UK CMIMLXE307024N
Central Battery System (CBS)70 lm70 lm-N/ATransparent2 YearsCE UK CMIMLXE307023
Central Battery System (CBS)70 lm70 lm-N/ATransparent2 YearsCE UK CMIMLXE307024
Central Battery System (CBS)335 lm335 lm-N/ATransparent2 YearsCE UK CMIMLXE340023N
Central Battery System (CBS)335 lm335 lm-N/ATransparent2 YearsCE UK CMIMLXE340024N
Central Battery System (CBS)400 lm400 lm-N/ATransparent2 YearsCE UK CMIMLXE340023
Central Battery System (CBS)400 lm400 lm-N/ATransparent2 YearsCE UK CMIMLXE340024
  • *NM: Non-maintained. The luminaire operates from emergency supply only upon failure of the normal mains supply.
  • *M/NM: Maintained/Non Maintained. With a third terminal which allows to switch off/on the Maintained mode when connected to mains supply.
PICT. DIANA/XENA IP66 UNIVERSAL MAN + ARROW
Reference
APF600
ACC. FIXATION 45º ARIAN
Reference
BRC045
ACC. FIXATION FLANGE ARIAN
Reference
BRC210
SMARTZ CONTROL UNIT+ UPS CSZ002+SAI002
Reference
CSZ003
CENTRAL DALI2
Reference
ZWEBDALI2
Series datasheet
Download dimension image
To access specific downloads for each reference, please first select it in the ‘Range’ tab